optibond.ru создан как площадка для обмена глубоким клиническим опытом

Effect of Modified Triple-Layer Application on the Bond Strength of Different Dental Adhesive Systems to Dentin.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Rim Bourgi; Naji Kharouf; Carlos Enrique Cuevas-Suárez; Monika Lukomska-Szymańska; Walter Devoto; Cynthia Kassis; Omar Hasbini; Davide Mancino; Youssef Haikel; Louis Hardan

Publication details

Journal of functional biomaterials · 2023 · Vol. 14 · No. 10

Publication date (as recorded): 2023-10-16

PMID: 37888187

Abstract (original)

The goal of this article was to assess the effect of modified triple-layer application (MTLA) in conjunction with the active bonding technique on the bond strength of four adhesive systems to dentinal substrate. The adhesives tested were Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE). The adhesives were applied according to the following strategies: single active application (A) and triple adhesive layer application including Active-Passive-Passive (APP); AAP; and AAA. The micro-tensile bond strength test was evaluated following 24 h or 6 months of storage. The composite-dentin interface morphology was investigated using scanning electron microscopy. The data were statistically analyzed with a significance level of α = 0.05. At 24 h of aging, all of the factors tested were not significant ( > 0.05) for CSE. For OBFL, OBU, and PBU, statistically higher values were observed for the A technique ( < 0.05). Plus, there were no significant variances between the APP, AAP, and AAA techniques ( > 0.05) for OBFL and PBU. However, for OBU, there were no significant differences between the A and AAA techniques ( > 0.05). After 6 months of aging, the A technique showed statistically higher values when compared to the other techniques ( < 0.01), except for OBFL, where the A and AAA techniques showed promising outcomes. When comparing the bond strength values of 24 h and 6 months, only for PBU, all of the techniques used resulted in bond strength stability over time ( > 0.05). Thicker adhesive layers were observed when MTLA was applied. Only the OBFL adhesive showed the formation of resin tags in all of the modalities tested. The bonding performances of the different application techniques used were material-dependent. p p p p p p

Source: https://pubmed.ncbi.nlm.nih.gov/37888187/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

Shear Bond Strength of Adhesives Placed following Selective Removal of Red-Fluorescing Carious Dentine in vitro.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее