optibond.ru создан как площадка для обмена глубоким клиническим опытом

Efficacy of universal bonding agents as desensitizers: in vitro and in vivo studies.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Xue Cai; Rongyu Cao; Xiaoyan Wang

Publication details

BMC oral health · 2026 · Vol. 26 · No. 1

Publication date (as recorded): 2026-01-28

PMID: 41612333

Abstract (original)

BACKGROUND: Dentin hypersensitivity (DH) is a highly challenging and persistent dental complaint. This study aimed to evaluate the in vitro durability of the universal dentin bonding agents Single Bond Universal (SBU) and OptiBond Universal compared with a specialized desensitizer, Hybrid Coat (HC), and to assess the desensitizing efficacy of SBU and HC in vivo over a 1-year follow-up period. METHODS: Dental root samples were prepared and treated with the three agents. After 24 h, 3 months, and 6 months, longitudinal sections of the root samples were examined under scanning electron microscopy, and adhesive layer thicknesses were measured. A split-mouth, blinded, randomized controlled trial was then conducted to compare the efficacy of SBU and HC for DH relief, using the visual analog scale (VAS). Assessments were performed at baseline, immediately post-application, and at 1, 3, 6, 9, and 12 months of follow-up, using standardized cold air stimulus protocols. The difference in VAS scores between pre- and post-application was used to measure efficacy. RESULTS: The adhesive layer created by SBU was thinner than that created by HC; however, the HC layer degraded more rapidly. After 6 months of water aging, root surfaces in the HC group were exposed, whereas those in the SBU group remained covered. The in vivo study demonstrated that SBU provided desensitizing efficacy comparable to that of HC over the 12-month period. CONCLUSIONS: Within the limitations of the present study, it can be concluded that the universal bonding agent SBU is effective and durable when applied as a desensitizer. Its efficacy is comparable to that of a dedicated desensitizing treatment. TRIAL REGISTRATION: NCT07197437 ( https://www.clinicaltrials.gov ), Date of Registration: 15/09/2025. (Retrospectively registered).

Source: https://pubmed.ncbi.nlm.nih.gov/41612333/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

Effect of Etching Mode on the Dentin Bond Durability of Universal Adhesives.

Следующая публикация

Effects of Calcium Silicate-Based Sealer Residues on Adhesive Bonding to Coronal Dentin: An in Vitro Study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее