optibond.ru создан как площадка для обмена глубоким клиническим опытом

Repair Bond Strength of Ion-Releasing Versus Conventional Resin Composites.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Jenny Buhl; Matej Par; Andrea Gubler; Tobias T Tauböck

Publication details

Materials (Basel, Switzerland) · 2026 · Vol. 19 · No. 6

Publication date (as recorded): 2026-03-10

PMID: 41900565

Abstract (original)

With the growing clinical use of ion-releasing resin composites, their repairability has become an important consideration in minimally invasive restorative dentistry. Therefore, this study investigated the repair bond strength of a universal composite restorative to commercially available and experimental ion-releasing resin composite materials. Specimens ( = 8 per group) were produced from three commercially available ion-releasing composite materials (ACTIVA BioACTIVE-RESTORATIVE, Cention Forte, Beautifil II), one experimental ion-releasing resin composite containing 20 wt% bioactive glass fillers, and two conventional resin composites (3M Filtek Supreme XTE, Ceram.x Spectra ST), and aged by thermal cycling in artificial saliva (5000 cycles, 5-55 °C). Substrate surfaces were sandblasted (AlO, 50 µm), silanized (Monobond Plus), and repaired using adhesive (OptiBond FL) and universal resin composite (Ceram.x Spectra ST). After further thermal cycling, micro-tensile repair bond strength was assessed and analyzed using one-way ANOVA followed by Tukey's post hoc test. Failure modes were determined by stereomicroscopy (25× magnification) and statistically compared among the groups. Highest mean repair bond strength values were obtained for ACTIVA BioACTIVE-RESTORATIVE, Beautifil II, and 3M Filtek Supreme XTE (53.8, 46.2, and 43.0 MPa, respectively), which did not differ significantly among each other. ACTIVA BioACTIVE-RESTORATIVE attained significantly higher bond strength than the experimental composite, Ceram.x Spectra ST, and Cention Forte, and showed the highest incidence of cohesive failures (40%). No significant bond strength differences were detected among Beautifil II, 3M Filtek Supreme XTE, experimental composite, Ceram.x Spectra ST, and Cention Forte (36.2-46.2 MPa). In conclusion, ion-releasing resin composites can be repaired with conventional universal composite and show repair bond strength values at least as high as those of conventional composite materials. n 2 3

Source: https://pubmed.ncbi.nlm.nih.gov/41900565/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

Investigating the Effect of Saliva Contamination at Different Time Intervals on Micro-Shear Bond Strength of Dentin with Immediate Dentin Sealing.

Следующая публикация

Wear performance of different bulk-fill class II resin composite restorations: 3-year clinical evaluation.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее