optibond.ru создан как площадка для обмена глубоким клиническим опытом

Effect of double-layer application techniques on the dentin micro-tensile bond strength of universal adhesives.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Gülşah Tonga; Hüseyin Hatırlı; Kübra Bahar

Publication details

BMC oral health · 2025 · Vol. 25 · No. 1 · Pages/article no. 1231

Publication date (as recorded): 2025-07-21

PMID: 40696338

Abstract (original)

This study aimed to evaluate the immediate and 6-month dentin micro-tensile bond strength (µTBS) of three universal adhesives applied using different double-layer application techniques. BACKGROUND BACKGROUND

Sixty-five human molar teeth were divided into 13 groups (n = 5) based on adhesive systems and application procedures. Three universal adhesives (G-Premio Bond, GC Corp.; GP, OptiBond Universal, Kerr; OB and Single Bond Universal, 3 M ESPE; SB) and a two-step self-etch adhesive (Clearfil SE Bond, Kuraray Noritake Dental; CSE) were tested. Universal adhesives were applied according to the manufacturer's instructions-(SL-MI) or three different double-layer application procedures: (1) the first adhesive layer was applied without either air thinning or light curing-(DL1), (2) air thinning without light curing the first layer-(DL2), (3) with air thinning and polymerisation each layer-(DL3). The two-step self-etch group was applied according to the manufacturer's instructions. µTBS was measured immediately, after 3 months and 6 months of water storage. Statistical analyses were conducted using Three-Way ANOVA (p< 0.05). METHODS METHODS

For the immediate and 3-month water storage of SB and GP, the highest µTBS values were observed in Group DL2, while for OB, Group DL3 exhibited the highest µTBS values (p< 0.05). After 6 months of water storage, differences among the application procedures were not significant for GP and OB (p> 0.05). The two-step self-etch system demonstrated higher µTBS than all universal adhesive systems at all test periods (p< 0.05). RESULTS RESULTS

The application of universal adhesives in two layers, particularly by thinning the first layer with air and polymerising after the second layer, positively affects immediate and 3-month µTBS. However, the benefits of double-layer application on 6-month µTBS appear to be material dependent. CONCLUSION CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/40696338/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

The Effect of Immediate Dentin Sealing Using Different Universal Adhesives on the Bond Strength of Pretreated Monolithic Zirconia to Dentin and Microscopic Morphological Alterations.

Следующая публикация

Influences of different fiber-reinforced biobases on the fracture strength and failure mode of lithium disilicate overlay restorations (a comparative study). in vitro

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее