optibond.ru создан как площадка для обмена глубоким клиническим опытом

Curing modes affects micro-tensile bond strength and durability of dual curing resin cements to dentin.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Zimeng Li; Xiaoyuan Yan; Negin Toufani; Hidehiko Sano; Jiale Fu

Publication details

Frontiers in bioengineering and biotechnology · 2024 · Vol. 12 · Pages/article no. 1511099

Publication date (as recorded): 2023-12-31

PMID: 39911815

Abstract (original)

To evaluate the effects of curing modes on the micro-tensile bond strength and durability of 6 different dual curing resin cements to dentin. BACKGROUND UNASSIGNED

84 human molars were divided into 7 groups (n = 12), and were further distributed into two subgroups according to the two curing modes: light-curing (L) and self-curing (D) (n = 6). The 6 dual-cured resin cements were: DU (Duolink, Bisco), TC (TheraCem, Bisco), MS (Multilink Speed, Ivoclar), N3 (Nexus 3 Universal, Kerr), R2 (RelyX U200, 3M) and RU (RelyX Ultimate, 3M). The universal adhesives were: All Bond Universal (Bisco); Adhesive Universal Vivapen (Ivoclar); Optibond Versa Adhesive (Kerr); Scotch Bond Universal Adhesive (3M). RU was placed directly on processed adhesive layer without light-curing, set as group 7. Micro-tensile bond strength test was carried out after 37°C water storage for 24 h, 3 months and 6 months, respectively. Three-way ANOVA and Games-Howell test were performed by SPSS 19.0 (α = 0.05). METHODS UNASSIGNED

The Three-way ANOVA indicated that bonding performance was significantly affected by curing mode (p = 0.000, F = 1,237.510), resin cement (p = 0.000, F = 59.507) and storage time (p = 0.000, F = 97.888). The interaction of these three factors was significant (p = 0.017, F = 2.071). RESULTS UNASSIGNED

The bonding strength and durability of dual curing resin cements were significantly improved by light-curing process. In addition, the bonding strength of resin cements with different experimental condition was material depended. Among all tested resin cements, N3 exhibits the most favorable outcomes. CONCLUSION UNASSIGNED

A dual curing procedure is recommended in clinical application. Among all tested resin cements, N3 exhibits the most favorable outcomes. CLINICAL RELEVANCE UNASSIGNED

Source: https://pubmed.ncbi.nlm.nih.gov/39911815/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

Effect of sodium hypochlorite, ethylenediaminetetraacetic acid, and dual-rinse irrigation on dentin adhesion using an etch-and-rinse or self-etch approach.

Следующая публикация

Warm Air Delivery in Adhesive Application: Effect on Bonding Performance and Morphological Outcomes.