optibond.ru создан как площадка для обмена глубоким клиническим опытом

Operator Experience Does Not Affect the Reliability of Universal Adhesives’ Bond Strength; Adhesive Type Does.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Marwa Bawazir; Sibel A Antonson

Publication details

The journal of adhesive dentistry · 2026 · Vol. 28 · Pages/article no. 99-110

Publication date (as recorded): 2026-06-22

PMID: 42333824

Abstract (original)

To determine the influence of operators' experience, dentin moisture condition (DMC), and adhesive type on shear bond strength, and evaluate the consistency of adhesive performance under these conditions to demonstrate clinical reliability. PURPOSE OBJECTIVE

Six hundred sound dentin surfaces were randomly divided by five dentists with at least 10 years of experience (n = 300/5 dentists) and five first-year dental students without dental experience (n = 300/5 students). Each operator applied universal (UA) (Adhese Universal, Ivoclar) and etch-and-rinse (ERA) (OptiBond FL, Kerr) adhesives (n = 60/adhesive type) before and after receiving demonstration on the manufacturers' recommended application techniques by the principal investigator (PI), on wet, moist, and dry dentin surfaces (n = 5/DMC). DMCs were obtained by the PI before the operators applied the adhesives. The PI applied composite restorations (Tetric EvoCeram Bulk Fill, Ivoclar) and polymerized for 20 s. Shear bond strength (SBS) test was conducted after 24 h storage at 37°C, in 100% humidity. Boxplot, Log Worth, and Tukey HSD were used for statistics. METHODS AND MATERIALS METHODS

The median SBS of ERA obtained by dentists was 17.79 MPa with an interquartile range (IQR) of 19.61, while students showed a lower median of 13.52 MPa with IQR of 15.81. The UA showed consistency in SBS and reduced variability across operators with median SBS by dentists and students (25.53 MPa and 24.96 MPa, respectively), with narrower IQRs of 10.6 and 7.3, respectively. SBS of UA was significantly higher than ERA (P 0.001). UA obtained 7.38 MPa ± 0.89 greater SBS than ERA. While no difference in SBS by operator was observed for UA, dentists obtained 1.65 MPa ± 0.73 greater SBS than students with ERA. Dry and moist dentin surface conditions yielded higher SBS values compared to wet surfaces (P 0.001 and P 0.002, respectively), with no significant differences observed between moist and dry surfaces. RESULTS RESULTS

The tested UA provided reliable outcomes regardless of operator and DMC. CONCLUSION CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42333824/


Rubberdamology
Глобальный аудит

Глобальное сравнение адгезивных систем: IV, V, VI, VII, VIII поколений

Масштабный академический синопсис доказательной базы PubMed. Сравнительный анализ устойчивости гибридного слоя к гидролизу, физика «водных деревьев» в упрощенных бондах и обоснование тотального превосходства многокомпонентного запечатывания дентина в рамках стандартов RSBC.

OptiBond FL
Глобальный аудит

Полный реестр научных статей о применении OptiBond FL

Массив в 401 исследование по OptiBond FL — это колоссальный объем данных, который наглядно объясняет, почему этот материал официально признан мировым научным сообществом «золотым стандартом» адгезии (Dreweck et al., PMID: 34919728; Peumans et al., PMID: 37435814).

Поделиться этой информацией
URL публикации
Предыдущая публикация

The effect of microstructural, compositional, and rheology-based properties of universal adhesive systems on bond strength.

Следующая публикация

Level of research and scientific interest in immediate dentin sealing: A global bibliometric network analysis.